SerVision CVG-M Installation Guide
Connecting Devices to the CVG-M 20
Figure 18: Connecting the module to the converter, the CVG-M, and the power supply
Connecting an Activator
Activators are external devices such as alarms and lights that can be turned on by the system in response to an
event. Essentially, the unit functions as an on/off switch for the device. The unit activates the activator by closing
the circuit of its power supply. One activator can be connected directly to the unit. In addition, if you wish, you can
connect an IA-3126-2 relay board to the unit. This makes it possible to connect up to 16 additional activators to the
unit (see Connecting Sensors and Activators Using an IA Relay Board, page 21).
In addition to the activator itself, you will need 16 AWG red and black cables to connect an activator to the unit.
To connect an activator directly to the unit:
1. Install the activator in its desired location in accordance with the manufacturer's instructions.
2. Connect the two contacts of the activator to the Out1 connector on the CVG-M, as illustrated in figure 19. It
does not matter which wire you connect to each contact.
Connect to RS232/485
connector on the CVG-M
(Y) Data +
(G) Data -
(R) +Vs
(B) GND
Connect to power
supply (-)
Connect to power
supply (+)